Skip to main content

BioPhotometerr D30 Reference Filter Set

Catalog No.
C16-1471-725
Manufacturer No.
6133928004
Manufacturer Name
EPPENDORF NORTH AMERICA
Quantity
1
Unit of Measure
EA
Price: $3,712.09
List Price: $4,124.54

The Eppendorf BioPhotometer D30 is the third generation of Eppendorf's well-established line of BioPhotometers. The small instrument clearly processes data, records at fixed wavelengths and makes evaluating results fast and simple.

Enjoy exclusive benefits including discounted pricing on orders by contacting our Sales Executives to open an account.

Adding to cart… The item has been added
The Eppendorf BioPhotometer D30 is the third generation of Eppendorf's well-established line of BioPhotometers. The small instrument clearly processes data, records at fixed wavelengths and makes evaluating results fast and simple. For specific methods, additional measurements are recorded and displayed as a graph, making impurities easier and quicker to identify. The Eppendorf BioPhotometer D30 is the 3rd generation of Eppendorf BioPhotometers which have become an established standard in the field of life sciences. It utilizes fixed wavelengths, making the Eppendorf BioPhotometer D30 the ideal device for quick and precise routine applications. The ultra-stable Xenon light source quickly lights up for immediate instrument use. Data is clearly processed making the evaluation of results fast and simple while minimizing mistakes. Additional help menus assist the user and offer an additional level of security. Relevant ratios are automatically determined for the corresponding applications. The Eppendorf BioPhotometer D30 offers the option of recording a scan for specific applications in the UV range. This allows a quick visual identification of contaminants in the sample. Nucleic acid purification is a major application in molecular laboratories. Purity and homogeneity of the sample are important considerations for subsequent applications. In practice, nucleic acids are purified with the help of commercially available kits which allow for the separation of most cellular components. However, the presence of proteins or other organic components in the eluate may not be entirely eliminated. When purifying nucleic acid without a kit, additional contamination risks are posed by the chemicals used in the process, e.g. phenol or ethanol from a phenol/chloroform extraction. To ensure minimum contamination of the sample, it is essential to verify its purity by photometric measurements. The ratios of the absorbance values at the wavelengths 230 nm, 260 nm and 280 nm (260 nm/230 nm and 260 nm/280 nm), provide a clear picture of the purity of a nucleic acid sample. The following values represent a pure DNA sample: A260/A230 ≥ 2.0 A260/A280 = 1.8 – 2.0 In general, the purity of a DNA solution is easily defined using purity ratios. It is possible that reduced purity may be attributed to the fact that the sample is solubilized in water instead of in buffer. Since water and buffer have different properties, the absorbance of the sample being measured will be affected by this disparity. For this reason, the BioPhotometer D30 is capable of recording a “Purity Scan” which displays the absorbance properties of a sample graphically, thus enabling fast and simple visual quality control. In addition, all important raw data pertaining to the DNA sample are displayed in table format. The table optionally lists the purity ratios (A260/A230 and A260/A280), the absorbance values (raw data), as well as the background absorbance, e.g. at 320 nm. Thus, the two display formats complement each other perfectly to allow for an evaluation of the quality of a DNA sample. Features Absorption measurements for one or more fixed wavelengths Scan for specific UV applications with automatically determined purity ratios Preprogrammed applications for quick start and applications with evaluation via factor, standard or standard series Integrated application and results memory Data transfer via USB interface, Ethernet or via e-mail and direct printout of results Xenon flash lamp with very long lifetime Guided software process to minimize errors Help box with explanation of each individual step in 5 languages Compatible with microvolume measuring cells and standard cuvettes Integrated self-test and calibration history Applications Nucleic acid quantification Direct protein quantification (UV 280 nm) Microvolume measurement via µCuvette G1.0 for highly concentrated samples Bacteria growth measurement (OD 600) Colorimetric assays for protein quantification, e.g., BCA, Bradford, Lowry 340 nm: assays using NADPH or NAPH 405 nm: assays using para-nitrophenol 490 nm: cytotoxicity assay
UPC:
41115700
Condition:
New
Availability:
3 Days
Weight:
1.00 Ounces
HazmatClass:
No
WeightUOM:
LB
MPN:
6133928004


Cenmed Satisfaction Guarantee

At Cenmed, your confidence and satisfaction are paramount. We guarantee the quality and reliability of our extensive range of clinical and laboratory supplies. If you're not completely satisfied with your purchase, we offer a straightforward return process and dedicated support to resolve your concerns promptly. Our commitment ensures that you can order with confidence, knowing that Cenmed is dedicated to superior service and customer satisfaction. Trust us to meet your needs with every order, backed by our promise of excellence. Learn more in Help & FAQs.


"Cenmed provides me access to the same products/services normally reserved for much larger labs than mine. I was presently surprised by their product offering."

LAB DIRECTOR


"We utilized Cenmed's capabilities for a variety of projects around the world. They are a valued partner and supplier."

PHARMACEUTICAL SUPPLY CHAIN LEADER


"The reps are very good at finding products for customers in this period of supply chain issues."

SCOTT BEHMAN


"Your customer service has been excellent and makes me excited about purchasing with Cenmed in the future!!"

PROCUREMENT + BILLING COORDINATOR AT PHARMA.