Skip to main content

C3/FB-Dpl

Aladdin

Catalog No.
C09-0822-728
Manufacturer No.
C409471-0.5ml
Manufacturer Name
Aladdin Scientific
Quantity
1
Unit of Measure
EA
Price: $534.35
List Price: $593.72

General DescriptionC3/FB-Depleted Serum is normal human serum in which C3 and factor B (fB) have been removed by immunoaffinity chromatography. The product is tested for the absence of C3 and factor B activity by testing classical and alternative

Enjoy exclusive benefits including discounted pricing on orders by contacting our Sales Executives to open an account.

Adding to cart… The item has been added
General DescriptionC3/FB-Depleted Serum is normal human serum in which C3 and factor B (fB) have been removed by immunoaffinity chromatography. The product is tested for the absence of C3 and factor B activity by testing classical and alternative pathway function and for the absence of C3 and factor B proteins by double immunodiffusion. The C3/FB-depleted serum is certified to exhibit less than 5% classical pathway and alternative pathway activities. A functional classical pathway can be reconstituted by addition of purified C3 protein (1.3 mg/mL) whereas a functional alternative pathway can be reconstituted by addition of purified C3 protein (1.3 mg/mL) and factor B protein (0.2 mg/mL) indicating that all other complement components necessary for classical and alternative pathway activation are present. After reconstitution with C3 (1.3 mg C3/mL) the C3/FB-Depleted Serum is certified to possess a functional classical pathway for complement activation whereas after reconstitution with C3 (1.3 mg C3/mL) and factor B (0.2 mg/mL), the product is certified to possess a functional alternative pathway for complement activation (Morgan, B.P. (2000); Dodds, A.W. and Sim, R.B. (1997)). Although a functional lectin pathway should also be reconstituted by the addition of similar concentrations of C3, the function of this pathway is not tested.Note that there is a weak C3 by-pass mechanism whereby the convertase C4b,C2a is able to activate C5 (Rawal, N. & Pangburn, M.K. 2003) and form C5b-9 complexes capable of causing low grade lysis. This system of C5 activation is functional in both the classical and the lectin pathways and is approximately 1000-fold less active than in the presence of C3.Physical Characteristics & Structure C3/FB-Depleted Serum is supplied as a clear, straw-colored liquid containing all proteins of normal human serum except C3 and factor B. FunctionC3/FB-Depleted Serum is tested for classical pathway activity by hemolytic assays using antibody-sensitized sheep erythrocytes and for alternative pathway function using rabbit erythrocytes. The depleted serum is reconstituted with 1.3 mg/mL C3 and 0.2 mg/mL factor B and retested to verify that functional classical and alternative pathways are restored. The Certificate of Analysis provided with each lot gives a description of the assays and specific titers for the depleted and reconstituted sera compared to normal human serum. AssaysThe unit of classical pathway activity is the CH50 and for the alternative pathway it is the AP50. A CH50 unit is the amount of complement needed to lyse 50% of 1 x 10⁸ EA cells (antibody-sensitized sheep erythrocytes when that amount of serum is incubated with the EA in GVB⁺⁺ in a total volume of 1.5 mL for 60 min at 37℃. See the Certificate of Analysis for lot specific values. An AP50 is defined as the amount of complement yielding 50% lysis of 1.5 x 10⁷ rabbit erythrocyteswhen incubated for 30 min at 37℃ in a total reaction volume of 100 µL of GVBo containing a final MgEGTA concentration of 5 mM. Lectin pathway activity of C3/FB-Depleted Serum is not tested, but it would be expected to be inactive due to the absence of C3. ApplicationsC3/FB-Depleted Serum is used as a source of serum with minimal ability to activate any of the three pathways of complement. However, C1 can be activated as well as the lectin pathway complexes of the lectins and MASPs. These complexes will then activate C2 that will attach to C4 generating the convertase C4b,C2a which is able to activate C5 (Rawal, N. & Pangburn, M.K. 2003) via a weak C3 by-pass mechanism. This system of C5 activation is functional in both the classical and the lectin pathways and is approximately 1000-fold less active than in the presence of C3.Precautions/Toxicity/HazardsThe source is human serum, therefore precautions appropriate for handling any bloodderived product must be used even though the source was shown by certified tests to be negative for HBsAg and for antibodies to HCV, HIV-1 and HIV-II.Hazard Code: B WGK Germany 3 MSDS is available upon request. ReferencesDodds, A.W. and Sim, R.B. editors (1997) Complement. A Practical Approach (ISBN 019963539) Oxford University Press, Oxford.Morgan, B.P. ed. (2000) Complement Methods and Protocols. (ISBN 0-89603-654-5) Humana Press, Inc., Totowa, New Jersey.Rawal N, Pangburn MK. (2003) Formation of high affinity C5 convertase of the classical pathway of complement. J. Biol. Chem. 278: 38476-83. Specifications and Purity: >50 mg protein/mL, 0.22 µm filtered. Related Document: https://ald-pub-files.oss-cn-shanghai.aliyuncs.com/aladdinsci/pdp/sds/1/C409471-SCI_4677e29316d53c4416374ecdd09e8c83.pdf.
UPC:
12352202
Condition:
New
Availability:
8-12 weeks
Weight:
1.09 Ounces
HazmatClass:
No
WeightUOM:
LB
MPN:
C409471-0.5ml
Product Size:
0.5ml


Cenmed Satisfaction Guarantee

At Cenmed, your confidence and satisfaction are paramount. We guarantee the quality and reliability of our extensive range of clinical and laboratory supplies. If you're not completely satisfied with your purchase, we offer a straightforward return process and dedicated support to resolve your concerns promptly. Our commitment ensures that you can order with confidence, knowing that Cenmed is dedicated to superior service and customer satisfaction. Trust us to meet your needs with every order, backed by our promise of excellence. Learn more in Help & FAQs.


"Cenmed provides me access to the same products/services normally reserved for much larger labs than mine. I was presently surprised by their product offering."

LAB DIRECTOR


"We utilized Cenmed's capabilities for a variety of projects around the world. They are a valued partner and supplier."

PHARMACEUTICAL SUPPLY CHAIN LEADER


"The reps are very good at finding products for customers in this period of supply chain issues."

SCOTT BEHMAN


"Your customer service has been excellent and makes me excited about purchasing with Cenmed in the future!!"

PROCUREMENT + BILLING COORDINATOR AT PHARMA.