Skip to main content

CLEARANCE ITEM: ORIGINAL LIST PRICE OF LOWEST UOM - $348.05 (C08-0512-912)

Catalog No.
C08-0512-912
Manufacturer No.
F2513-5
Manufacturer Name
NATIONAL SCIENTIFIC
Quantity
100
Unit of Measure
PK
Price: $433.97
List Price: $482.18

Non-sterile, sample prep membrane filters 7 membrane types Female Luer-Lock inlet, male Luer-slip outlet Solvent resistant polypropylene housings PES, GMF, Polypropylene and Cellulose Acetate membranes are certified for Ion Chromatography The

Enjoy exclusive benefits including discounted pricing on orders by contacting our Sales Executives to open an account.

Adding to cart… The item has been added
Non-sterile, sample prep membrane filters 7 membrane types Female Luer-Lock inlet, male Luer-slip outlet Solvent resistant polypropylene housings PES, GMF, Polypropylene and Cellulose Acetate membranes are certified for Ion Chromatography The polypropylene housings with all Target syringe filters are solvent resistant and exhibit low extractables. Ideal for filtering chromatography solvents and samples when combined with low extractable Nylon, Regenerated Cellulose or PTFE membranes. Meets the requirements of 21 CFR 177.1520. All types are supplied in packs of 100. Cellulose Acetate (CA) is a very low protein binding membrane ideal for aqueous based samples. An excellent choice for maximum protein recovery in filtrate. Laboratory studies show that CA membranes bind less protein than PVDF or Polysulfone membranes. When used with a glass prefilter, CA is ideal for tissue culture media filtration and sensitive biological samples. The prefilter increases yield. Cellulose Acetate is certified for Ion Chromatography. Regenerated Cellulose (RC) is a hydrophilic, solvent resistant, low protein binding membrane. It is the membrane of choice for low non-specific binding (biological analysis, protein, peptides). Suitable for removing particulates from HPLC samples prior to injection. Compatible with all HPLC solvents and aqueous samples in the 3 to 12 pH range. Used for particle removal and degassing of solvents. Extractables with water are less than 1%. Glass MicroFiber (GMF) membranes are commonly used as prefilters to remove large particulates and to extend the load capacity of the membrane. Membrane of choice for dissolution testing. GMF is certified for Ion Chromatography. Nylon (NY) membranes are naturally hydrophilic, solvent resistant, do not require pre-wetting and have low extractables. Can withstand solution up to 50°C. Can be used with organic or aqueous solutions. Flow rate is excellent. Not recommended for strong acids or bases. Commonly used for general laboratory filtration. Nylon binds protein and is not recommended when high protein recovery is needed. Available with glass prefilter. Polypropylene (PP) is a hydrophilic material that exhibits a wide range of chemical compatibility to organic solvents. A good choice for HPLC sample filtration when performing chromatography analysis. Highly solvent resistant. Low, non-specific absorbing membranes for maximum protein recovery. Well-suited for biological sample filtration. Also available with 1.0 µm built-in glass prefilter. Polypropylene is certified for Ion Chromatography. Polytetrafluoroethylene ( PTFE) is a hydrophobic membrane chemically resistant to all solvents, acids and bases. Membrane has high mechanical strength and can withstand high temperature liquids. Does not impart any extractables to the filtrate. PTFE blocks water vapor, making it ideal for transducer protectors. Also excellent for filtering and degassing organic and highly basic mobile phase solutions for liquid chromatography. Available with glass prefilter. Polyethersulsulfone (PES) is a naturally hydrophilic membrane that gives higher flow rates, lower extractables and low binding of protein and nucleic acids and can be used with high temperature liquids. PES is mechanically strong and resistant to a broad range of aqueous solvents. PES is the filter of choice for for tissue culture work. PES is certified for Ion Chromatography. Polyvinylidene Difluoride (PVDF) is a hydrophilic, solvent resistant membrane that exhibits low levels of UV adsorbing extractables. Low non-specific adsorbing membrane for maximum protein recovery in critical analysis. Also well suited for biological sample filtration.
UPC:
41104900
Condition:
New
Availability:
3 Days
Weight:
1.00 Ounces
HazmatClass:
No
WeightUOM:
LB
MPN:
F2513-5


Cenmed Satisfaction Guarantee

At Cenmed, your confidence and satisfaction are paramount. We guarantee the quality and reliability of our extensive range of clinical and laboratory supplies. If you're not completely satisfied with your purchase, we offer a straightforward return process and dedicated support to resolve your concerns promptly. Our commitment ensures that you can order with confidence, knowing that Cenmed is dedicated to superior service and customer satisfaction. Trust us to meet your needs with every order, backed by our promise of excellence. Learn more in Help & FAQs.


"Cenmed provides me access to the same products/services normally reserved for much larger labs than mine. I was presently surprised by their product offering."

LAB DIRECTOR


"We utilized Cenmed's capabilities for a variety of projects around the world. They are a valued partner and supplier."

PHARMACEUTICAL SUPPLY CHAIN LEADER


"The reps are very good at finding products for customers in this period of supply chain issues."

SCOTT BEHMAN


"Your customer service has been excellent and makes me excited about purchasing with Cenmed in the future!!"

PROCUREMENT + BILLING COORDINATOR AT PHARMA.