Skip to main content
Image coming soon

Corningr BioCoatT FluoroBlokT 3.0 mm Inserts In Two 24-Well

Catalog No.
C08-0356-257
Manufacturer No.
354597
Manufacturer Name
Corning - DISCOVERY LABWARE
Quantity
24
Unit of Measure
CS
Price: $660.72
List Price: $734.13

Cell culture on permeable membranes permits diffusion of media components to both apical and basolateral cell surfaces Membranes with extracellular matrix (ECM) further improve in vitro cell culture systems by providing cells with relevant protein

Enjoy exclusive benefits including discounted pricing on orders by contacting our Sales Executives to open an account.

Adding to cart… The item has been added
Cell culture on permeable membranes permits diffusion of media components to both apical and basolateral cell surfaces Membranes with extracellular matrix (ECM) further improve in vitro cell culture systems by providing cells with relevant protein substrates Corning® BioCoat™ Cell Culture Inserts contain Corning® Falcon™ Cell Culture Inserts coated with extracellular matrix (ECM) and are packaged ready-to-use in Corning® Falcon® Companion Plates. Cell culture on microporous membranes has been shown to promote differentiation of a variety of epithelial and mesenchymal cells in vitro, especially in the presence of ECM. ECM is a vital component of the cellular microenvironment in vivo. The use of ECM growth substrates in vitro has been shown to promote cell growth, cell-specific morphology, and differentiated function. For example, collagen I and fibronectin have been used on microporous inserts to establish barrier function in monolayers of intestinal epithelial and endothelial cells, to culture a renal cell line that expresses kidney-specific peptide transporters, and to culture keratinocytes. Additionally, Corning® BioCoat™ Matrigel®™ Matrix coated inserts have been used to maintain polarized secretion in uterine, thyroid and mammary epithelial cells. The track-etched polyethylene teraphthalate (PET) membranes used in Corning® BioCoat™ Cell Culture Inserts have individual cylindrical pores in a broad range of sizes including 0.4, 1.0, 3.0, and 8.0 µm. Applications include: Promotion of epithelial cell polarity Differentiation of a variety of cell types Transport and permeability studies Transendothelial migration Tumor cell invasion assays Chemotaxis and haptotaxis assays In vitro toxicology Co-culture studies The PET membrane offers several advantages: Low binding properties minimize the loss of small molecules, including low molecular weight proteins and other natural and synthetic compounds. Therefore, the membrane is ideal or transport or intercellular communications studies Low pore-density membranes are transparent, allowing living cells to be viewed with a phase contrast microscope Exceptional durability assures membranes are compatible with most solvents used during fixation and staining protocols for light and electron microscopy Membranes will not tear or curl and remain easy to handle when removed from insert housing Corning® BioCoat™ Cell Culture Inserts offer: Corning® Falcon® Cell Culture Inserts’ innovative hanging design facilitates pipetting and reduces risk of medium wicking Corning® Falcon® Companion Plates’ labyrinth lid design and condensation rings reduce evaporation and risk of contamination Choice of 6-, 12-, and 24-well plate sizes An extensive selection of ECMs for improved cell attachment morphology, and functionality Corning® BioCoat™ Cell Culture Inserts are available with the following selection of ECMs:Three-Dimensional Matrices: Corning® Matrigel® Matrix, Fibrillar CollagenThin-Layer Matrices: Collagen I, Fibronectin, Collagen iv, Laminin Quality Control: All cell culture inserts are tested for ability to promote cell attachment and spreading or differentiation (cell type used is specific for each ECM). Tested and found negative for bacteria and fungi. Storage and Stability: Corning® BioCoat™ Collagen I, Collagen iv, Fibrillar Collagen, Fibronectin, and Laminin Inserts stable for = three months at 2-8°C. Corning® BioCoat™ Matrigel®™ Matrix Inserts stable for = three months at -20°C. Corning® BioCoat™ Control Inserts and Deep-Well Plates stable at room temperature.
UPC:
24102201
Condition:
New
Availability:
3 Days
Weight:
1.00 Ounces
HazmatClass:
No
WeightUOM:
LB
MPN:
354597


Cenmed Satisfaction Guarantee

At Cenmed, your confidence and satisfaction are paramount. We guarantee the quality and reliability of our extensive range of clinical and laboratory supplies. If you're not completely satisfied with your purchase, we offer a straightforward return process and dedicated support to resolve your concerns promptly. Our commitment ensures that you can order with confidence, knowing that Cenmed is dedicated to superior service and customer satisfaction. Trust us to meet your needs with every order, backed by our promise of excellence. Learn more in Help & FAQs.


"Cenmed provides me access to the same products/services normally reserved for much larger labs than mine. I was presently surprised by their product offering."

LAB DIRECTOR


"We utilized Cenmed's capabilities for a variety of projects around the world. They are a valued partner and supplier."

PHARMACEUTICAL SUPPLY CHAIN LEADER


"The reps are very good at finding products for customers in this period of supply chain issues."

SCOTT BEHMAN


"Your customer service has been excellent and makes me excited about purchasing with Cenmed in the future!!"

PROCUREMENT + BILLING COORDINATOR AT PHARMA.