Skip to main content

CWhipro Circulating DNA Midi Kit (C09-1524-777)

Aladdin

Catalog No.
C09-1524-777
Manufacturer No.
C665715-10T
Manufacturer Name
Aladdin Scientific
Quantity
1
Unit of Measure
Set
Price: $550.88
List Price: $612.09

Product content:Component:C665715-10T:C665715-50T:Buffer CL:45 mL:220 mL:Buffer CB(concentrate):60 mL:300 mL:Buffer GTL:15 mL:60 mL:Buffer GW1(concentrate):3 mL:13 mL:Buffer GW2(concentrate):3 mL:15 mL:Buffer EBL:2 mL:10 mL:Proteinase K:100 mg:3×180

Enjoy exclusive benefits including discounted pricing on orders by contacting our Sales Executives to open an account.

Adding to cart… The item has been added
Product content:Component:C665715-10T:C665715-50T:Buffer CL:45 mL:220 mL:Buffer CB(concentrate):60 mL:300 mL:Buffer GTL:15 mL:60 mL:Buffer GW1(concentrate):3 mL:13 mL:Buffer GW2(concentrate):3 mL:15 mL:Buffer EBL:2 mL:10 mL:Proteinase K:100 mg:3×180 mg:Proteinase K Storage Buffer:5 mL:30 mL:Spin Columns DG With Collection Tubes:10:50:Tube Extenders (20 mL):10:50:VacConnectors:10:50:Centrifuge Tubes (L-1.5 mL):10:50:Product Introduction:This kit is suitable for the extraction of free DNA from fresh or frozen serum, plasma, amniotic fluid, urine and other cell-free body fluids.This kit adopts adsorption columns that can specifically bind nucleic acids and a unique buffer system.After the sample is lysed, the free DNA binds to the silica gel membrane under high salt conditions, and the free DNA elutes from the silica gel membrane at low salt and high pH. This kit uses the negative pressure method and is also equipped with extension tubes that can handle up to 5 ml of sample. The purified DNA is of high yield and good quality, with maximum removal of proteins, pigments, lipids and other inhibitory impurity contamination. The free DNA obtained from purification is of stable and reliable quality and can be directly used in molecular biology experiments such as PCR, fluorescence quantitative PCR and second generation sequencing.Self-contained reagents: :anhydrous ethanol, isopropanol:Preparation and important precautions before the experiment:1.Add the specified amount of Proteinase K Storage Buffer to each tube of Proteinase K powder, allow it to dissolve completely, and then store at -20℃. Do not leave the prepared Proteinase K at room temperature for a long time, and avoid repeated freezing and thawing to avoid affecting its activity. The other components can be stored stably for one year in a dry, room temperature (15-30°C) environment. For longer storage, store at 2-8°C.Cat. No.C665715-10T:C665715-50T:Proteinase K Storage Buffer:5 mL:Add to each bottle 9 mL:2. Repeated freezing and thawing of samples should be avoided, as this may result in smaller extracted DNA fragments and reduced extraction.3. This kit can extract cfDNA from up to 5mL of serum plasma, 4mL of urine.4. Before first use isopropyl alcohol should be added to Buffer CB according to the instructions on the reagent bottle label, mixed well, and labeled on the reagent bottle label.5. Before the first use, anhydrous ethanol should be added to Buffer GW1 and Buffer GW2 according to the instructions on the label of the reagent bottle, mixed well, and labeled on the label of the reagent bottle.6. Before use, please check whether Buffer CL, Buffer CB appears to be crystallized or precipitated, if there is any crystallization or precipitation, please re-dissolve Buffer CL, Buffer CB by incubation at 56℃ in a water bath, mix well and then use.7. The water bath was preheated to 60°C before the start of the experiment.8. The elution buffer Buffer EBL can be preheated to 60°C.9. Negative pressure device.Operation steps:Serum, plasma samples (1-5mL):1. Sample processing: Add 1mL of serum/plasma sample to the centrifuge tube (self-prepared), if the sample is less than 1mL, add PBS solution to make up to 1mL volume.Note: When the sample volume exceeds 1mL, please increase the amount of Proteinase K, Buffer CL, and Buffer CB reagents in equal proportion, and the specific amount of reagents to be added can be referred to Exhibit 1.2. Add 100 μL of Proteinase K to the above solution and mix well.3. Add 800 μL of Buffer CL and shake vigorously for at least 30 seconds.4. Incubate at 60°C for 30 min, during which time invert and mix several times.5. Add 1800 μL of Buffer CB (check for addition of isopropanol before use) and mix upside down 10 times or shake vigorously for 15-30 seconds.6. Ice bath for 5 minutes.7. To properly connect the negative pressure unit, insert the connection tubes (VacConnectors) into the sockets of the negative pressure unit.8. Insert the adsorption column (Spin Column DG) onto the connection tube.9. Insert the extension tubes (Tube Extenders) into the adsorption column with open caps.CAUTION: Ensure that the connecting tube, adsorbent column and extension tube are securely connected to prevent leakage.10. Add all the mixed solution after the ice bath into the extension tube, turn on and adjust the negative pressure to -900~-800mbar, and slowly suck out the solution in the tube. When the solution is completely sucked away, turn off the negative pressure switch and carefully remove the extension tube when the pressure returns to 0mbar.11. Add 500μL of Buffer GW1 to the column (check whether anhydrous ethanol is added before use), turn on and adjust the negative pressure to -900~-800mbar, wait for the solution to be completely absorbed, and then turn off the negative pressure switch.12. Add 750μL Buffer GW2 to the adsorption column (check whether anhydrous ethanol is added before use), turn on and adjust the negative pressure to -900~-800mbar, wait until the solution is completely absorbed, and turn off the negative pressure switch.13. Add 750μL of anhydrous ethanol to the adsorption column, turn on and adjust the negative pressure to -800~-900mbar, wait until the solution is completely absorbed, and turn off the negative pressure switch.14. When the pressure returns to 0 mbar, remove the column and place it in a new Collection Tube and centrifuge at 12,000 rpm for 3 minutes, pouring off the waste liquid from the tube. Leave the column at room temperature for a few minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with the subsequent enzymatic reaction.15. Place the adsorption column in a new 1.5mL centrifuge tube (Centrifuge Tube), add 20-150 μL Buffer EBL to the center of the adsorption column overhanging the center of the adsorption column, let it stand at room temperature for 3 minutes, centrifuge it at 12,000 rpm for 1 minute, collect the DNA solution, and store the DNA at -20℃.Exhibit 1: Recommended amount of reagents to be added for different serum/plasma sample sizes:Urine samples (1-4 ml):1. Sample handling:Add 1mL of urine sample to a centrifuge tube (provided). If the sample is less than 1mL, add PBS solution to make up to 1mL volume.Note: When the sample volume exceeds 1mL, add Proteinase K, Buffer GTL, Buffer CL, and Buffer in equal proportions.CB reagent dosage, the exact amount of reagent added can be found in Exhibit 2.2. Add 125μL of Proteinase K to the above solution and mix well.3. Add 1mL Buffer CL, 250μL Buffer GTL and shake vigorously for at least 30 seconds.4. Incubate at 60°C for 30 minutes, during which time mixing was inverted several times.5. Add 3.6mL Buffer CB (check for addition of isopropanol before use) and shake vigorously for 15-30 seconds.6. Ice bath for 5 minutes.7. Connect the negative pressure unit correctly by inserting the connection tubes (VacConnectors) into the sockets of the negative pressure unit.8. Insert the adsorption column (Spin Column DG) onto the connection tube.9. Insert Tube Extenders into the open-capped adsorption column.CAUTION: Ensure that the connecting tube, adsorbent column and extension tube are securely connected to prevent leakage.10. Add all the mixed solution after the ice bath into the extension tube, turn on and adjust the negative pressure to -900~-800mbar, and slowly suck out the solution in the tube. When the solution is completely sucked away, turn off the negative pressure switch and carefully remove the extension tube when the pressure returns to 0mbar.11. Add 500μL of Buffer GW1 to the column (check whether anhydrous ethanol is added before use), turn on and adjust the negative pressure to -900~-800mbar, wait for the solution to be completely absorbed, and then turn off the negative pressure switch.12. Add 750μL Buffer GW2 to the adsorption column (check whether anhydrous ethanol is added before use), turn on and adjust the negative pressure to -900~-800mbar, wait until the solution is completely absorbed, and turn off the negative pressure switch.13. Add 750μL of anhydrous ethanol to the adsorption column, turn on and adjust the negative pressure to -900~-800mbar, wait until the solution is completely absorbed, and turn off the negative pressure switch.14. When the pressure returns to 0 mbar, remove the column and place it in a new Collection Tube and centrifuge at 12,000 rpm for 3 minutes, pouring off the waste liquid from the tube. Leave the column at room temperature for a few minutes to dry thoroughly.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can interfere with the subsequent enzymatic reaction.15. Place the adsorption column in a new 1.5mL centrifuge tube (Centrifuge Tube), add 20-150 μL of Buffer EBL to the center of the adsorption column overhanging the column, let it stand at room temperature for 3 minutes, centrifuge it at 12,000 rpm for 1 minute, collect the DNA solution, and store the DNA at -20°C.Exhibit 2: Recommended amount of reagents to be added for different urine sample sizes:Connection Diagram of Tube Extenders (20mL), Spin Column DG, VacConnectors Specifications and Purity: Negative pressure method
UPC:
41116133
Condition:
New
Availability:
8-12 weeks
Weight:
17.64 Ounces
HazmatClass:
No
WeightUOM:
LB
MPN:
C665715-10T
Product Size:
10T


Cenmed Satisfaction Guarantee

At Cenmed, your confidence and satisfaction are paramount. We guarantee the quality and reliability of our extensive range of clinical and laboratory supplies. If you're not completely satisfied with your purchase, we offer a straightforward return process and dedicated support to resolve your concerns promptly. Our commitment ensures that you can order with confidence, knowing that Cenmed is dedicated to superior service and customer satisfaction. Trust us to meet your needs with every order, backed by our promise of excellence. Learn more in Help & FAQs.


"Cenmed provides me access to the same products/services normally reserved for much larger labs than mine. I was presently surprised by their product offering."

LAB DIRECTOR


"We utilized Cenmed's capabilities for a variety of projects around the world. They are a valued partner and supplier."

PHARMACEUTICAL SUPPLY CHAIN LEADER


"The reps are very good at finding products for customers in this period of supply chain issues."

SCOTT BEHMAN


"Your customer service has been excellent and makes me excited about purchasing with Cenmed in the future!!"

PROCUREMENT + BILLING COORDINATOR AT PHARMA.