Skip to main content

EA (antibody-sensitized sheep erythrocytes) (C09-0882-297)

Aladdin

Catalog No.
C09-0882-297
Manufacturer No.
E501290-20ml
Manufacturer Name
Aladdin Scientific
Quantity
1
Unit of Measure
EA
Price: $1,694.44
List Price: $1,882.71

AbsorbanceA412 nm = 0.87 at 1/50 dilution in deionized waterGeneral DescriptionSheep red blood cells coated with rabbit anti-sheep erythrocyte antiserum(hemolysin) have traditionally been used to assay the activity of the complement classicalpathway

Enjoy exclusive benefits including discounted pricing on orders by contacting our Sales Executives to open an account.

Adding to cart… The item has been added
AbsorbanceA412 nm = 0.87 at 1/50 dilution in deionized waterGeneral DescriptionSheep red blood cells coated with rabbit anti-sheep erythrocyte antiserum(hemolysin) have traditionally been used to assay the activity of the complement classicalpathway in serum samples. These assays yield the CH50 titer of the serum (Morgan, B.P. (2000); Dodds, A.W. and Sim, R.B. (1997)). EA are supplied at assay-ready concentrations in the traditional buffer used in CH50 assays (GVB⁺⁺). They can usually be used for 2 weeks after preparation. They are shipped cold, but are not harmed by extended periods at room temperature (note that they circulate 60-90 days a 37℃ in vivo). They should be washed once before each use (3 min at 500 to 1000 x g at 4℃) and resuspended at the original concentration in GVB++to reduce background. This procedure may also be used to concentrate the cells. This may be accomplished by reducing the volume used to resuspend the cells.Physical CharacteristicsEA are made with IgM antibodies for the following reason. IgM is approximately 100 times more efficient at activating the classical pathway than IgG because C1q mustbind to at least two Fc domains on antibodies for activation to occur. Thus, in the most sensitive assays it has been estimated that as few as 10 IgM per EA can cause lysis while with IgG lysis requires approximately 1000 IgG per EA (Ross, G.D. (1986)). This is primarily because in IgM there are five closely spaced Fc domains in fixed positions on each molecule. Because the spacing of IgG molecules on a surface is more random, it is less probable to find two to five IgG molecules in the correct positions on the surface of a cell to bind and activate C1. Assays Although the CH50 titer is widely used and serves as the primary clinical test for complement activity, the CH50 assay procedure is not entirely standardized. In research labs there are as many procedures as there are labs, but all are basically similar and give useful results. A detailed step-by-step typical CH50 titer method may be obtained from upon request. Briefly, a complement-containing serum sample is diluted sothat the final dilutions in the assay are in the range from 1/100 to 1/500. Controls include two tubes with no complement for the 0% lysis background and two tubes in which water is used in place of buffer for the 100% lysis control. Assay tubes should be set up while on wet ice. The volume is brought to 1.3 mL with GVB⁺⁺(or water), the tubes are mixed and 0.2 mL of cells at 5 x 108 EA/mL are added and mixed. The reactions should be incubated for 60 min in a 37℃water bath with remixing at approximate 10 min intervals. After one hour, the remaining cells are spun down (500-1000 x g for 3 min) and the absorbance of the supernatant determined at 541 nm in a 1 cm cuvette. There are a variety of mathematical methods for graphing the results. An almost perfect straight line should be obtained by plotting on a log-log plot the microliters of serum used in each assay on the x axis and y/(1-y) on the y axis. The term “y” refers to the proportion of cells lysed and would be zero at 0 % lysis, 0.3 at 30 % lysis ,0.5 at 50% lysis and so on. The CH50 value of the complement sample is obtained from the point where the line crosses 1.0 on the y axis (50 % lysis) and is calculated as follows: CH50 = 1000 divided by the volume (in µL) of serum giving 50% lysis. For example, if 50% lysis was achieved with 5.6 µL of serum then the CH50 = 179 units/mL. It should be noted that different CH50 values can be obtained on what should be identical samples. This is the result of the vast number of variables involved in CH50 determinations including the fact that sheep erythrocytes harvested in the spring are more easily lysed than cells from blood drawn in the fall, no two hemolysin antibody lots are the same because they are made from antiserum raised in rabbits, etc. Applications EA may be used to determine the CH50 hemolytic titer of serum, that is, the CH50 (see Assays above). They can be used to titer the functional activity of individual complement components using depleted serums. They may also be used to prepare cells carrying activated complement intermediates (Morgan, B.P. (2000); Dodds, A.W. and Sim, R.B. (1997)). EA are incubated with C1 to make (EAC1) or C1 and C4 (EAC14). EAC14 cells may be incubated with C2 to prepare EAC142 cells bearing the classical pathway C3 convertase and EAC142 may be incubated with C3 to prepare EAC1423 cells which carry the C5 convertase. Each intermediate may be used to assay fluid phase components for functional complement activity. For example, lysis of EAC142 cells is extremely sensitive to low C3 concentrations and this can be used to titer C3 complement activity even in complex mixtures such as serum.RegulationSheep erythrocytes (Es) are used for human complement assays partly for convenience, but also because they lack membrane-bound regulators of human complement. No significant level of functional DAF, CD59 or CR1 exists on Es for human complement. Thus, Es are useful for their lack of membrane regulatory activities. Specifications and Purity: 5 x 10⁸ cells/mL. Related Document: https://ald-pub-files.oss-cn-shanghai.aliyuncs.com/aladdinsci/pdp/sds/1/E501290-SCI_09b5d285a1c348b8cf7cdbe5e4ad094b.pdf.
UPC:
12352203
Condition:
New
Availability:
8-12 weeks
Weight:
2.47 Ounces
HazmatClass:
No
WeightUOM:
LB
MPN:
E501290-20ml
Product Size:
20ml


Cenmed Satisfaction Guarantee

At Cenmed, your confidence and satisfaction are paramount. We guarantee the quality and reliability of our extensive range of clinical and laboratory supplies. If you're not completely satisfied with your purchase, we offer a straightforward return process and dedicated support to resolve your concerns promptly. Our commitment ensures that you can order with confidence, knowing that Cenmed is dedicated to superior service and customer satisfaction. Trust us to meet your needs with every order, backed by our promise of excellence. Learn more in Help & FAQs.


"Cenmed provides me access to the same products/services normally reserved for much larger labs than mine. I was presently surprised by their product offering."

LAB DIRECTOR


"We utilized Cenmed's capabilities for a variety of projects around the world. They are a valued partner and supplier."

PHARMACEUTICAL SUPPLY CHAIN LEADER


"The reps are very good at finding products for customers in this period of supply chain issues."

SCOTT BEHMAN


"Your customer service has been excellent and makes me excited about purchasing with Cenmed in the future!!"

PROCUREMENT + BILLING COORDINATOR AT PHARMA.