General description
Assurance® GDS is an advanced genetic detection system for food pathogens. The MPX Top 7 STEC is an automated nucleic acid amplification system for the detection of E. coli O157:H7 and the "Top Six" non-O157 Shiga Toxigenic E. coli (STEC). The Top Six non-O157 STEC are defined as E. coli belonging to serogroups O103, O111, O121, O145, O26, or O45 that possess both the eae gene and at least one of the shiga toxin genes (stx1 or stx2). Assurance® GDS MPX Top 7 STEC utilizes a proprietary PickPen® IMS-based sample preparation procedure to quickly and effectively capture organisms belonging to the 7 specific Top STEC O serogroups prior to genetic analysis for the associated pathogenicity genes.
Application
Assurance® GDS MPX Top 7 STEC is suitable for the detection of E. coli O157:H7 and the “Top Six†non-O157 Shiga Toxigenic E. coli (STEC) in foods, ingredients, and environmental samples.
Features and Benefits
- Following sample preparation with IMS against the Top 7 O groups, samples are analyzed with a single multiplex assay for the presence of (eae), stx1, and stx2
- Assurance® GDS MPX Top 7 STEC assay includes a separate target and differentiated result for E. coli O157:H7
- Single-step 10-18 h enrichment in mEHEC®, enrichment media common to all BioControl methods for E.coli O157:H7, Shiga Toxin genes, and Top STEC
Components
- MPX Top STEC Amplification Tubes
- Top 7 STEC Concentration ReagentResuspension Buffer TqTop STEC Wash Solution
Compatibility
BioControl GDS
Testing Method
PCR, Immunomagnetic Separation (IMS)
Legal Information
AOAC is a registered trademark of AOAC International
Assurance is a registered trademark of BioControl Systems, Inc.
Assurance GDS is a registered trademark of BioControl Systems, Inc.
PICKPEN is a registered trademark of BioControl Systems, Inc.
mEHEC is a registered trademark of BioControl Systems, Inc.
Agency: AOAC®. (PTM). Quality Level: 200. shelf life: 6‑. 12 . mo.. packaging: pkg of 100 . tests. manufacturer/tradename: Assurance GDS®. , BioControl Systems 71015-100, BioControl Systems 71015-576. technique(s): PCR: suitable. web metadata keyword.default: microbialanalysismicrobialanalysis. application(s): food and beverages
pathogen testing. compatibility: for use with GDS Rotor-Gene. storage temp.: 2-8°C. suitability: enterovirulent E. coli (EEC) (shiga toxigenic). Pictograms: GHS05. Signal Word: Warning. Hazard Statements: H290. Precautionary Statements: P234 - P390. Hazard Classifications: Met. Corr. 1. Storage Class Code: 8A - Combustible, corrosive hazardous materials. WGK: WGK 3.