Skip to main content

GoldHi EndoFree Plasmid Maxi Kit (C09-1136-172)

Aladdin

Catalog No.
C09-1136-172
Manufacturer No.
G665587-2T
Manufacturer Name
Aladdin Scientific
Quantity
1
Unit of Measure
SET
Price: $175.15
List Price: $194.61

Product content: Component G665587 2 preps G66558710 preps Buffer P1 30 mL 125 mL Buffer P2 30 mL 125 mL Buffer E3 30 mL 125 mL Buffer PS 15 mL 30 mL Buffer PW (concentrate)

Enjoy exclusive benefits including discounted pricing on orders by contacting our Sales Executives to open an account.

Adding to cart… The item has been added
Product content: Component G665587 2 preps G66558710 preps Buffer P1 30 mL 125 mL Buffer P2 30 mL 125 mL Buffer E3 30 mL 125 mL Buffer PS 15 mL 30 mL Buffer PW (concentrate) 10 mL 50 mL Endo-Free Buffer PW 30 mL 125 mL Endo-Free Buffer EB 10 mL 30 mL RNase A (10 mg/mL) 600 μL 2 mL Spin Columns DZ with Collection Tubes 2 10 Centrifuge Tubes(50 mL) 2 10Product Introduction:Endotoxins are a common pollutant in plasmid extraction. Due to the high sensitivity of eukaryotic cells to endotoxins, the presence of endotoxins in plasmids can greatly reduce the transfection efficiency of eukaryotic cells. This kit provides a simple and efficient new method for extracting endotoxin free plasmids. Based on the alkaline lysis method for cell lysis, a unique silicon matrix membrane adsorption technology is used to efficiently and specifically bind plasmid DNA; At the same time, a special buffer system and endotoxin removal buffer are used to effectively remove impurities such as endotoxins, genomic DNA, RNA, proteins, etc. Each time, 100-300mL of bacterial solution can be processed to obtain up to 2mg of transfected plasmid DNA, and the entire extraction process only takes 50 minutes. The plasmid obtained from this kit has high purity and extraction capacity, making it particularly suitable for cell transfection. It can also be used for DNA sequencing, PCR, in vitro transcription, endonuclease digestion and other experiments.Self prepared reagents: anhydrous ethanol, isopropanol.Notes:1. All components can be stably stored for 1 year in a dry, room temperature (15-30 ℃) environment. The adsorption column can be stored for a longer time at 2-8 ℃. 2.Buffer P1 with RNase A added can be stably stored for 6 months at 2-8 ℃. Before use, add RNase A to Buffer P1 (add all RNase A provided in the reagent kit), mix well, and store at 2-8 ℃. Before use, it is necessary to leave it at room temperature for a period of time, and then use it after returning to room temperature.3.Before the first use, anhydrous ethanol should be added to the Buffer PW according to the instructions on the reagent bottle label.4. Before use, please check if there is any crystallization or precipitation in Buffer P2 and Buffer E3. If there is any crystallization or precipitation, you can take a water bath at 37 ℃ for a few minutes to restore clarity.5. Note that Buffer P2 and Buffer E3 contain irritating substances. Please wear gloves when operating and immediately cover the lid after use.6. The adsorption column treated with Buffer PS should be left for 15-30 minutes before passing the mixed solution through the column. The effect is good, and it is not recommended to leave it for more than 30 minutes.7.The amount and purity of plasmid extraction are related to factors such as bacterial culture concentration, strain type, plasmid size, and plasmid copy number.8. The amount of plasmid extracted bacterial solution should not exceed the recommended volume in Tables 1 and 2. The amount of P1, P2, and E3 solutions extracted from high copy plasmids is 12 mL each; For the extraction of low copy plasmids, the dosage of P1, P2, and E3 solutions should be adjusted according to the amount of bacterial solution, as shown in Table 3:Note: ODV=OD600 × V, where V is the amount of bacterial solution (mL); The recommended OD600 is 1-4.9. It is recommended to use the volume of lysis solution for low copy plasmids, as shown in the table below:Note: Taking OD600=4 as an example.Operation steps:1. Take 150 mL of overnight cultured bacterial solution and add it to a centrifuge tube (provided by oneself). Centrifuge 12000 × g for 2-3 minutes to collect bacteria, and try to discard all the supernatant as much as possible.2. Add 12 mL of Buffer P1 (please check if RNase A has been added first) to the centrifuge tube containing bacterial precipitation. Mix thoroughly with a pipette or vortex oscillator to suspend bacterial precipitation.Attention: If the bacterial blocks are not thoroughly mixed, it will affect the cracking effect, resulting in low extraction amount and purity. For low copy plasmids, the acting bacterial solutionWhen the quantity is large, it is necessary to increase the usage of P1, P2, and E3 proportionally, please refer to Table 3.3. Add 12 mL of Buffer P2 to the centrifuge tube, gently invert and mix 8-10 times, allowing the bacterial cells to fully lyse. Let it stand at room temperature for 5 minutes. At this point, the solution should become clear and viscous.Attention: Mix gently and do not shake vigorously to avoid interrupting genomic DNA and mixing genomic DNA fragments in the extracted plasmid.If the solution does not become clear, it indicates that the bacterial count may be too high and the lysis may not be complete. The bacterial count should be reduced.4. At this point, perform column equilibrium: add 2 mL of Buffer PS to the Spin Columns DZ that has been loaded into the collection tube, centrifuge at 12000 × g for 2 minutes, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. Note: After the completion of column equilibrium in step 4 (Bu ff er PS passing through the column), it is recommended to use it for step 7 (supernatant and isopropanol mixture passing through the column)A time difference of 15-30 minutes can increase the extraction yield.5. Add 12 mL of Buffer E3 to the centrifuge tube, immediately invert and mix 8-10 times. At this point, white flocculent precipitates appear, and let it stand at room temperature for 5 minutes. Centrifuge 12000 × g for 10 minutes and transfer the supernatant to a clean centrifuge tube (provided), taking care not to introduce sediment.Attention: Bu ff er E3 should be mixed immediately after addition to avoid local precipitation.6. Add 0.3 times the volume of the supernatant with isopropanol, invert and mix well.Attention: Adding too much isopropanol can easily lead to RNA contamination.7. Transfer the mixed solution of the supernatant and isopropanol to the equilibrium adsorption column DZ (loaded into the collection tube) in step 4. Centrifuge 12000 × g for 2 minutes, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube. Note: The maximum volume of the adsorption column is 15 mL, so the solution obtained in step 7 is passed through the column multiple times. If the inclination angle of the centrifuge rotor is large, it is recommended to add a solution volume of no more than 10 mL to the adsorption column to prevent liquid leakage.8. Add 10 mL of Buffer PW to the adsorption column (please check if anhydrous ethanol has been added first), centrifuge at 12000 × g for 2 minutes, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.9. Repeat step 8.10. Add 10 mL Endo Free Buffer PW to the adsorption column, centrifuge at 12000 × g for 2 minutes, discard the waste liquid in the collection tube, and place the adsorption column back into the collection tube.11. Place the adsorption column back into the collection pipe, centrifuge at 12000 × g for 5 minutes, discard the waste liquid, and place the adsorption column at room temperature for a few minutes to thoroughly dry the residual rinsing solution in the column.Note: The purpose of this step is to remove residual ethanol from the adsorption column, which can affect subsequent enzymatic reactions (such as enzyme digestion, PCR, etc.).12. Place the adsorption column in a new centrifuge tube, add 1-3mLEndo Free Buffer EB to the middle of the adsorption membrane, let it stand at room temperature for 2-5 minutes, centrifuge 12000 × g for 5 minutes, and collect the plasmid solution into the centrifuge tube- Store the plasmid at 20 ℃.Attention:1) To increase the recovery efficiency of plasmids, the obtained solution can be added back to the adsorption column, left at room temperature for 2-5 minutes, centrifuged at 12000 × g for 5 minutes, and collected into a centrifuge tube. 2) When the plasmid copy number is low or>10 kb, preheating the Endo Free Buffer EB in a water bath at 65-70 ℃ can increase the extraction efficiency.
UPC:
12352208
Condition:
New
Availability:
8-12 weeks
Weight:
17.64 Ounces
HazmatClass:
No
WeightUOM:
LB
MPN:
G665587-2T
Product Size:
2T


Cenmed Satisfaction Guarantee

At Cenmed, your confidence and satisfaction are paramount. We guarantee the quality and reliability of our extensive range of clinical and laboratory supplies. If you're not completely satisfied with your purchase, we offer a straightforward return process and dedicated support to resolve your concerns promptly. Our commitment ensures that you can order with confidence, knowing that Cenmed is dedicated to superior service and customer satisfaction. Trust us to meet your needs with every order, backed by our promise of excellence. Learn more in Help & FAQs.


"Cenmed provides me access to the same products/services normally reserved for much larger labs than mine. I was presently surprised by their product offering."

LAB DIRECTOR


"We utilized Cenmed's capabilities for a variety of projects around the world. They are a valued partner and supplier."

PHARMACEUTICAL SUPPLY CHAIN LEADER


"The reps are very good at finding products for customers in this period of supply chain issues."

SCOTT BEHMAN


"Your customer service has been excellent and makes me excited about purchasing with Cenmed in the future!!"

PROCUREMENT + BILLING COORDINATOR AT PHARMA.