Skip to main content

Human ADP ELISA Assay Kit

Aladdin

Catalog No.
C09-0738-198
Manufacturer No.
A486349-1kit
Manufacturer Name
Aladdin Scientific
Quantity
1
Unit of Measure
EA
Price: $1,012.68
List Price: $1,125.20

The reagent kit adopts a double antibody one-step sandwich enzyme-linked immunosorbent assay (ELISA). Add the sample, standard substance, and HRP labeled detection antibody to the pre coated micropores of adenosine diphosphate (ADP) antibody, then

Enjoy exclusive benefits including discounted pricing on orders by contacting our Sales Executives to open an account.

Adding to cart… The item has been added
The reagent kit adopts a double antibody one-step sandwich enzyme-linked immunosorbent assay (ELISA). Add the sample, standard substance, and HRP labeled detection antibody to the pre coated micropores of adenosine diphosphate (ADP) antibody, then incubate and thoroughly wash. Using substrate TMB for color development, TMB is converted to blue under the catalysis of peroxidase, and finally to yellow under the action of acid. The depth of color is positively correlated with adenosine diphosphate (ADP) in the sample. Measure the absorbance (OD value) using an ELISA reader at a wavelength of 450nm and calculate the sample concentration.Sample collection, processing, and preservation methods1. Serum: Use a test tube that does not contain pyrogens and endotoxins. Avoid any cell stimulation during the operation. After collecting blood, centrifuge at 3000 rpm for 10 minutes to quickly and carefully separate the serum and red blood cells.2. Plasma: EDTA, citrate or heparin anticoagulation. Centrifuge at 3000 rpm for 30 minutes to obtain the supernatant.3. Cell supernatant: Centrifuge at 3000 rpm for 10 minutes to remove particles and polymers.4. Tissue homogenization: Add an appropriate amount of physiological saline to the tissue and crush it. Centrifuge at 3000 rpm for 10 minutes to obtain the supernatant.5. Storage: If the sample is not tested in a timely manner after collection, please divide it into batches according to the amount used, freeze it at -20 ℃, avoid repeated freeze-thaw, thaw it at room temperature, and ensure that the sample is evenly charged and thawed.Self provided items1. Enzyme reader (450nm)2. High precision sampler and nozzle: 0.5-10uL, 2-20uL, 20-200uL, 200-1000uL3.37 ℃ constant temperature boxOperation precautions1. Store the reagent kit at 2-8 ℃ and equilibrate at room temperature for 20 minutes before use. The concentrated washing solution taken out of the refrigerator will have crystals, which is a normal phenomenon. The water bath is heated to completely dissolve the crystals before use.2. The Flat noodles not used in the experiment shall be immediately put back into the self sealing bag and sealed (low-temperature dry) for storage.3. S0 standard substance with a concentration of 0 can be considered as a negative control or blank; When operating according to the instructions, the sample has been diluted 5 times, and multiplying the final result by 5 is the actual concentration of the sample.4. Strictly follow the time, amount of liquid added, and sequence specified in the instruction manual for temperature cultivation.5. Shake all liquid components thoroughly before use.Kit composition名称96孔配置48孔配置备注微孔酶标板12孔×8条12孔×4条无标准品0.3mL*6管0.3mL*6管无样本稀释液6mL3mL无检测抗体-HRP10mL5mL无20×洗涤缓冲液25mL15mL按说明书进行稀释底物A6mL3mL无底物B6mL3mL无终止液6mL3mL无封板膜2张2张无说明书1份1份无自封袋1个1个无注:标准品(S0-S5)浓度依次为:0、400、800、1600、3200、6400 nmol/LPreparation of reagentstwenty × Dilution of washing buffer: Dilute distilled water at a ratio of 1:20, which is 20 parts of 1 part × Add 19 parts of distilled water to the washing buffer.Washing method1. Manual washing of the board: Shake off the liquid in the holes, fill each hole with washing solution, let it stand for 1 minute, shake off the liquid in the holes, pat dry on absorbent paper, and wash the board 5 times in this way.2. Automatic plate washer: Inject 350 cleaning solution into each hole μ L. Soak for 1 minute and wash the board 5 times.Operation steps1. Take out the required Flat noodles from the aluminum foil bag after 20 min of room temperature balance, and seal the remaining Flat noodles with a self sealing bag and put it back at 4 ℃.2. Set standard and sample wells, with different concentrations of standard added to each standard well μ L;3. Add the sample to be tested to the sample well first μ L. Add another sample diluent of 40 μ L; Blank holes are not added.4. Except for blank wells, add 100 detection antibodies labeled with horseradish peroxidase (HRP) to each well of the standard and sample wells μ L. Seal the reaction pores with a sealing film and incubate in a 37 ℃ water bath or constant temperature box for 60 minutes.5. Discard the liquid, pat dry on absorbent paper, fill each hole with washing solution, let it stand for 1 minute, shake off the washing solution, pat dry on absorbent paper, and repeat this process 5 times (the board can also be washed with a washing machine).6. Add 50 substrates A and B each to each well μ L. Incubate at 37 ℃ in dark for 15 minutes.7. Add 50 terminating liquids to each well μ L. Measure the OD values of each well at a wavelength of 450nm within 15 minutes.Result judgmentDraw standard curve: In the Excel worksheet, use the standard concentration as the x-axis and the corresponding OD value as the y-axis to draw the standard linear regression curve. Calculate the concentration values of each sample according to the curve equation.Reagent kit performance1. Accuracy: The correlation coefficient R between the standard linear regression and the expected concentration is greater than or equal to 0.9900.2. Sensitivity: The minimum detection concentration is less than 10 nmol/L.3. specificity: does not cross react with other soluble structural analogues.4. Repeatability: The coefficient of variation within and between boards is less than 15%.5. Storage: Store at 2-8 ℃, away from light and moisture.6. Validity period: 6 monthsDisclaimers1. The reagent kit is for research purposes only and shall not be used in clinical or human experiments. Otherwise, all consequences arising from it shall be borne by the experimenter, and our company shall not be responsible.2. Strictly follow the instructions for operation. If the experimenter violates the instructions, the consequences shall be borne by the experimenter. Specification: 96T/48T
UPC:
12161503
Condition:
New
Availability:
8-12 weeks
Weight:
3.53 Ounces
HazmatClass:
No
WeightUOM:
LB
MPN:
A486349-1kit
Product Size:
1kit


Cenmed Satisfaction Guarantee

At Cenmed, your confidence and satisfaction are paramount. We guarantee the quality and reliability of our extensive range of clinical and laboratory supplies. If you're not completely satisfied with your purchase, we offer a straightforward return process and dedicated support to resolve your concerns promptly. Our commitment ensures that you can order with confidence, knowing that Cenmed is dedicated to superior service and customer satisfaction. Trust us to meet your needs with every order, backed by our promise of excellence. Learn more in Help & FAQs.


"Cenmed provides me access to the same products/services normally reserved for much larger labs than mine. I was presently surprised by their product offering."

LAB DIRECTOR


"We utilized Cenmed's capabilities for a variety of projects around the world. They are a valued partner and supplier."

PHARMACEUTICAL SUPPLY CHAIN LEADER


"The reps are very good at finding products for customers in this period of supply chain issues."

SCOTT BEHMAN


"Your customer service has been excellent and makes me excited about purchasing with Cenmed in the future!!"

PROCUREMENT + BILLING COORDINATOR AT PHARMA.