Skip to main content

Ipatasertib dihydrochloride (C09-1140-292)

Aladdin

Catalog No.
C09-1140-292
Manufacturer No.
I650365-500mg
Manufacturer Name
Aladdin Scientific
Quantity
1
Unit of Measure
EA
Price: $1,731.81
List Price: $1,924.23

Ipatasertib dihydrochloride (GDC-0068 dihydrochloride) is a highly selective and ATP-competitive pan-Akt inhibitor with IC 50 s of 5, 18 and 8 nM for Akt1 , Akt2 and Akt3 , respectively.In VitroIpatasertib shows more than 600 and more than 100-fold

Enjoy exclusive benefits including discounted pricing on orders by contacting our Sales Executives to open an account.

Adding to cart… The item has been added
Ipatasertib dihydrochloride (GDC-0068 dihydrochloride) is a highly selective and ATP-competitive pan-Akt inhibitor with IC 50 s of 5, 18 and 8 nM for Akt1 , Akt2 and Akt3 , respectively.In VitroIpatasertib shows more than 600 and more than 100-fold selectivity for Akt1 in IC 50 against the closely related kinases PKA and p70S6K, respectively. When tested at 1 μM in a panel of 230 protein kinases, which includes 36 human AGC family members, Ipatasertib inhibits only 3 other kinases by more than 70% at 1 μM concentration (PRKG1α, PRKG1β, and p70S6K). IC 50 s measured for these 3 kinases are 98, 69, and 860 nM, respectively. Thus, with the exception of PKG1 (relative to which Ipatasertib is >10-fold more selective for Akt1), Ipatasertib displays a more than 100-fold selectivity for Akt1 over the next most potently inhibited non-Akt kinase, p70S6K, in the screening kinase panel. The relationship between pharmacokinetics (PK) and pharmacodynamics (PD) of Ipatasertib is investigated in 3 xenograft models that showed dose-dependent response to drug treatment: MCF7-neo/HER2, TOV-21G.x1, and LNCaP. The mean cell viability IC 50 of Ipatasertib in these 3 cell lines is 2.56, 0.44, and 0.11 μM, respectively. MCE has not independently confirmed the accuracy of these methods. They are for reference only.In VivoIpatasertib is typically efficacious in xenograft models in which Akt is activated because of genetic alterations including PTEN loss, PIK3CA mutations/amplifications, or HER2 overexpression. In these models, tumor growth delay, stasis, or regression is achieved at or below 100 mg/kg daily oral dose, which is the maximum dose tested in immunocompromised mice that is well tolerated. When tested in vivo, daily dosing of Ipatasertib in combination with RP-56976 induces tumor regression and stasis in the PC-3 and MCF7-neo/HER2 xenograft models, at doses where each single agent is ineffective or only causes modest tumor growth delay. Similarly, increased TGI is observed in the OVCAR3 ovarian cancer xenograft model when Ipatasertib is combined with NSC 241240. The combination of Ipatasertib with RP-56976 or NSC 241240 is tolerated with less than 5% body weight loss when compared with treatment with each chemotherapeutic agent alone. MCE has not independently confirmed the accuracy of these methods. They are for reference only.Cell AssayThe 384-well plates are seeded with 2,000 cells per well in a volume of 54 μL per well followed by incubation at 37°C under 5% CO 2 overnight (~16 hours). Compounds (e.g., Ipatasertib) are diluted in DMSO to generate the desired stock concentrations then added in a volume of 6 μL per well. All treatments are tested in quadruplicates. After 4 days incubation, relative numbers of viable cells are estimated using CellTiter-Glo and total luminescence is measured on a Wallac Multilabel Reader. The concentration of drug resulting in IC 50 is calculated from a 4-parameter curve analysis (XLfit) and is determined from a minimum of 3 experiments. For cell lines that failed to achieve an IC 50 , the highest concentration tested (10 μM) is listed. MCE has not independently confirmed the accuracy of these methods. They are for reference only.Animal administrationMice In vivo efficacy is evaluated in multiple tumor cell line- and patient-derived xenograft models. Cells or tumor fragments are implanted subcutaneously into the flank of immunocompromised mice. Female or male nude (nu/nu) or severe combined immunodeficient mice (SCID)/beige mice are used. The LuCaP35V patient-derived primary tumors are obtained; male mice are castrated before implantation of tumor fragments. After implantation of tumor cells or fragments into mice, tumors are monitored until they reached mean tumor volumes of 180 to 350 mm 3 and distributed into groups of 8 to 10 animals/group. Ipatasertib is formulated in 0.5% methylcellulose/0.2% Tween-80 (MCT) and administered daily (QD), via oral (per os; PO) gavage. RP-56976 is formulated in 3% EtOH/97% saline and dosed intravenously (IV) every week (QW) at 2.5 or 7.5 mg/kg. NSC 241240 is formulated in saline and dosed intraperitoneally (IP) weekly at 50 mg/kg. aladdin has not independently confirmed the accuracy of these methods. They are for reference only.Form:SolidIC50& Target:Akt1 5 nM (IC 50 ) Akt3 8 nM (IC 50 ) Akt2 18 nM (IC 50 ) PKA 3100 nM (IC 50 ). Specification: 0.99 Molecular Formula: C24H34Cl3N5O2 Molecular Weight: 530.92 PubChem CID: 62707512 Isomeric SMILES: C[C@@H]1C[C@H](C2=C1C(=NC=N2)N3CCN(CC3)C(=O)[C@H](CNC(C)C)C4=CC=C(C=C4)Cl)O.Cl.Cl
UPC:
12352107
Condition:
New
Availability:
8-12 weeks
Weight:
1.08 Ounces
HazmatClass:
No
WeightUOM:
LB
MPN:
I650365-500mg
CAS:
1396257-94-5
Product Size:
500mg


Cenmed Satisfaction Guarantee

At Cenmed, your confidence and satisfaction are paramount. We guarantee the quality and reliability of our extensive range of clinical and laboratory supplies. If you're not completely satisfied with your purchase, we offer a straightforward return process and dedicated support to resolve your concerns promptly. Our commitment ensures that you can order with confidence, knowing that Cenmed is dedicated to superior service and customer satisfaction. Trust us to meet your needs with every order, backed by our promise of excellence. Learn more in Help & FAQs.


"Cenmed provides me access to the same products/services normally reserved for much larger labs than mine. I was presently surprised by their product offering."

LAB DIRECTOR


"We utilized Cenmed's capabilities for a variety of projects around the world. They are a valued partner and supplier."

PHARMACEUTICAL SUPPLY CHAIN LEADER


"The reps are very good at finding products for customers in this period of supply chain issues."

SCOTT BEHMAN


"Your customer service has been excellent and makes me excited about purchasing with Cenmed in the future!!"

PROCUREMENT + BILLING COORDINATOR AT PHARMA.