Skip to main content
Exclusive Savings: Take 10% OFF All Cenmed Products | Upgrade Your Lab For Less Shop Now
US English

ALADDIN SCIENTIFIC

JC-10

JC-10 is an ideal fluorescent probe widely used to detect mitochondrial membrane potential △Ψm. Can detect cell, tissue or purified mitochondrial membrane potential.

Description

JC-10 is an ideal fluorescent probe widely used to detect mitochondrial membrane potential △Ψm. Can detect cell, tissue or purified mitochondrial membrane potential. When the mitochondrial membrane potential is high, JC-10 aggregates in the matrix of the mitochondria to form a polymer, which can produce red fluorescence; when the mitochondrial membrane potential is low, JC-10 cannot accumulate in the matrix of the mitochondria, at this time JC- 10 is a monomer, which can produce green fluorescence. In this way, it is very convenient to detect the change of mitochondrial membrane potential through the change of fluorescence color. The relative ratio of red and green fluorescence is commonly used to measure the ratio of mitochondrial depolarization. The decrease of mitochondrial membrane potential is a landmark event in the early stage of apoptosis. The decrease of cell membrane potential can be easily detected by the transition of JC-10 from red fluorescence to green fluorescence, and the transition from red fluorescence to green fluorescence of JC-10 can also be used as an early detection indicator of cell apoptosis. The maximum excitation wavelength of JC-10 monomer is 515nm and the maximum emission wavelength is 529nm; the maximum excitation wavelength of JC-10 polymer is 585nm and the maximum emission wavelength is 590nm. For actual observation, use the conventional settings for observing red fluorescence and green fluorescence.


Specifications & Purity: JC-10 is an ideal fluorescent probe widely used to detect mitochondrial membrane potential △Ψm. Can detect cell, tissue or purified mitochondrial membrane potential. When the mitochondrial membrane potential is high, JC-10 aggregates in the matrix of the mitochondria to form a polymer, which can produce red fluorescence; when the mitochondrial membrane potential is low, JC-10 cannot accumulate in the matrix of the mitochondria, at this time JC- 10 is a monomer, which can produce green fluorescence. In this way, it is very convenient to detect the change of mitochondrial membrane potential through the change of fluorescence color. The relative ratio of red and green fluorescence is commonly used to measure the ratio of mitochondrial depolarization. The decrease of mitochondrial membrane potential is a landmark event in the early stage of apoptosis. The decrease of cell membrane potential can be easily detected by the transition of JC-10 from red fluorescence to green fluorescence, and the transition from red fluorescence to green fluorescence of JC-10 can also be used as an early detection indicator of cell apoptosis. The maximum excitation wavelength of JC-10 monomer is 515nm and the maximum emission wavelength is 529nm; the maximum excitation wavelength of JC-10 polymer is 585nm and the maximum emission wavelength is 590nm. For actual observation, use the conventional settings for observing red fluorescence and green fluorescence.


Molecular Formula: C25H29Cl2IN4


Molecular Weight: 583.34


Storage Temperature: Protected from light;Store at -20°C


Shipped in: Ice chest + Ice pads


More Information: https://ald-pub-files.oss-cn-shanghai.aliyuncs.com/aladdinsci/pdp/sds/1/J141206-SCI_6d382918d8e0df77744420e9bd678caa.pdf


Specifications
UPC:
51173231
Weight:
1.06 Ounces
HazmatClass:
No
Quantity:
1
Unit of Measurement:
EA
WeightUOM:
LB
MPN:
J141206-1mg
Country of Origin:
China
Product Size:
1mg
Harmonized Tariff Code:
2931.90.90
Catalog No. C008B-273557
Price: $192.05
List Price: $213.39
  • Guaranteed quality & reliable delivery
  • Shipping Lead-Time: 14-21 Days
Adding to cart… The item has been added
Request a Quote

Enjoy exclusive benefits, including discounted pricing on bulk orders, by opening a Cenmed Business Account. Learn More.