Skip to main content
Exclusive Savings: Take 10% OFF All Cenmed Products | Upgrade Your Lab For Less Shop Now
US English

ALADDIN SCIENTIFIC

Mouse Neutrophil Isolation Kit (Negative Isolation) (C008B-266887)

The Mouse Neutrophil Isolation Kit (Negative Isolation) is used to isolate neutrophils from mouse bone marrow or other tissue single-cell suspensions by negative i solation. The principle is to use a cocktail of biotin-labeled...

Description

The Mouse Neutrophil Isolation Kit (Negative Isolation) is used to isolate neutrophils from mouse bone marrow or other tissue single-cell suspensions by negative i solation. The principle is to use a cocktail of biotin-labeled monoclonal antibodies against non-target cells (non-CD11b⁺ Ly-6G⁺ cells), followed by removal of these non-target cells using streptavidin-labeled magnetic beads, thereby achieving the isolation of mouse neutrophils. A magnetic separator is required for the isolation process.ApplicationsIsolation of neutrophils from mouse bone marrow, peripheral blood, or spleen.M1522422ComponentAppearance10T50T100TStorageM1522422ABiotin-Antibody MixLiquid20 μL100 μL200 μL2-8℃.M1522422BStreptavidin Magnetic BeadsLiquid200 μL1 mL1 mL×22-8℃.Cell Sample PreparationObtain cells and lyse red blood cellsCollect mouse bone marrow, spleen, or peripheral blood cells in a centrifuge tube and perform red blood cell lysis.Note: The red blood cell lysis step can be adjusted in volume and time depending on the tissue sample and the lysis buffer used. Typically, mouse peripheral blood requires a longer lysis time. A small amount of red blood cell residue will not affect the purity of isolated cells. Bone marrow cells can be processed directly without red blood cell lysis, but the purity of isolated neutrophils may decrease slightly (within 5%) as the proportion of red blood cells increases.FilterAfter lysis, resuspend the cells in PBS, filter the cell suspension through a 70 μm cell strainer, and centrifuge at 500 g for 5 min.Note: The cell suspension must be passed through a cell strainer to remove tissue and cell clumps; otherwise, subsequent cell isolation purity may be affected.Wash cellsAfter centrifugation, resuspend the cells in Isolation Buffer, wash the cells, centrifuge at 500 g for 5 min, and discard the supernatant.Note: Isolation buffer is PBS containing 2 mM EDTA and 2% fetal bovine serum (FBS), or PBS containing 2 mM EDTA and 0.5% BSA. The buffer must be pre-filtered through a 0.22 μm filter.Adjust cell densityResuspend the cells in Isolation Buffer to a density of 1×10⁸ cells/mL.Isolation ProtocolAdd Biotin-Antibody MixAdd 100 μL of cell suspension (1×10⁷ cells) to the bottom of a 1.5 mL centrifuge tube, then add 2 μL of Biotin-Antibody Mix. Mix well and incubate at 4°C for 10 min.Note: When adding the cell suspension, add it to the bottom of the tube, avoiding the tube wall. If isolating more cells, increase the volume of Biotin-Antibody Mix proportionally.Wash cells onceAfter incubation, add Isolation Buffer to bring the volume to 1.5 mL, and centrifuge at 500 g for 5 min.Note: If isolating a very large number of cells, use a 15 mL centrifuge tube, add Isolation Buffer to 5-10 mL, then centrifuge.Resuspend cellsAfter centrifugation, discard the supernatant and resuspend the cells in 100 μL of Isolation Buffer.Note: If isolating more cells, increase the volume of Isolation Buffer proportionally.Add Streptavidin Magnetic BeadsAdd 20 μL of washed Streptavidin Magnetic Beads to the centrifuge tube (the beads must be washed before use: vortex to resuspend the beads, transfer the required volume of beads to a 1.5 mL centrifuge tube, add 1 mL of Isolation Buffer, centrifuge at 10,000 g for 1 min or use a magnetic separator for 3 min, then discard the supernatant. Add 1 mL of Isolation Buffer and wash the beads once more, then resuspend the beads in the same volume of Isolation Buffer as originally taken. For example, if 20 μL of beads are taken, resuspend them in 20 μL of Isolation Buffer after washing). Mix thoroughly and incubate at 4°C for 10 min.Note: If isolating more cells, increase the volume of Streptavidin Magnetic Beads proportionally. For example, to isolate 5×10⁷ cells, add 10 μL of Biotin-Antibody Mix and 100 μL of Streptavidin Magnetic Beads to 500 μL of cell suspension. If isolating fewer than 1×10⁷ cells, adjust the cell suspension volume to 100 μL, then add 2 μL of Biotin-Antibody Mix and 20 μL of Streptavidin Magnetic Beads.Transfer and diluteAfter incubation, transfer the mixture to a FACS tube, add Isolation Buffer to a total volume of 2.5 mL, and mix thoroughly by pipetting up and down (avoid vigorous shaking or inverting).Magnetic separationPlace the FACS tube containing the cell suspension on a magnetic separator and let stand for 5 min.Collect neutrophilsGently pour the cell suspension into a sterile centrifuge tube (do not remove the FACS tube from the magnetic separator while pouring). This cell suspension contains the purified mouse neutrophils. Centrifuge at 500 g for 5 min, then discard the supernatant and collect the cells.Resuspend for further useWash the cells as required for your experiment, then resuspend them in the desired buffer or culture medium for subsequent molecular or cell biology experiments.Isolation PerformanceNeutrophils were isolated from C57BL/6 mouse bone marrow cells. Cells before and after isolation were stained with FITC anti-mouse Ly-6G antibody (clone 1A8) and PE anti-mouse CD11b antibody (clone M1/70) and analyzed by flow cytometry. The purity of neutrophils before and after isolation was 43.5% and 95.1%, respectively.PrecautionsAvoid freezing the magnetic beads and antibody mix during use and storage.Low-retention pipette tips and centrifuge tubes are recommended to avoid loss of beads and antibodies due to adsorption.This product must be used with a magnetic separator.For research use only.


Specifications & Purity: The Mouse Neutrophil Isolation Kit (Negative Isolation) is used to isolate neutrophils from mouse bone marrow or other tissue single-cell suspensions by negative i solation. The principle is to use a cocktail of biotin-labeled monoclonal antibodies against non-target cells (non-CD11b⁺ Ly-6G⁺ cells), followed by removal of these non-target cells using streptavidin-labeled magnetic beads, thereby achieving the isolation of mouse neutrophils. A magnetic separator is required for the isolation process.ApplicationsIsolation of neutrophils from mouse bone marrow, peripheral blood, or spleen.M1522422ComponentAppearance10T50T100TStorageM1522422ABiotin-Antibody MixLiquid20 μL100 μL200 μL2-8℃.M1522422BStreptavidin Magnetic BeadsLiquid200 μL1 mL1 mL×22-8℃.Cell Sample PreparationObtain cells and lyse red blood cellsCollect mouse bone marrow, spleen, or peripheral blood cells in a centrifuge tube and perform red blood cell lysis.Note: The red blood cell lysis step can be adjusted in volume and time depending on the tissue sample and the lysis buffer used. Typically, mouse peripheral blood requires a longer lysis time. A small amount of red blood cell residue will not affect the purity of isolated cells. Bone marrow cells can be processed directly without red blood cell lysis, but the purity of isolated neutrophils may decrease slightly (within 5%) as the proportion of red blood cells increases.FilterAfter lysis, resuspend the cells in PBS, filter the cell suspension through a 70 μm cell strainer, and centrifuge at 500 g for 5 min.Note: The cell suspension must be passed through a cell strainer to remove tissue and cell clumps; otherwise, subsequent cell isolation purity may be affected.Wash cellsAfter centrifugation, resuspend the cells in Isolation Buffer, wash the cells, centrifuge at 500 g for 5 min, and discard the supernatant.Note: Isolation buffer is PBS containing 2 mM EDTA and 2% fetal bovine serum (FBS), or PBS containing 2 mM EDTA and 0.5% BSA. The buffer must be pre-filtered through a 0.22 μm filter.Adjust cell densityResuspend the cells in Isolation Buffer to a density of 1×10⁸ cells/mL.Isolation ProtocolAdd Biotin-Antibody MixAdd 100 μL of cell suspension (1×10⁷ cells) to the bottom of a 1.5 mL centrifuge tube, then add 2 μL of Biotin-Antibody Mix. Mix well and incubate at 4°C for 10 min.Note: When adding the cell suspension, add it to the bottom of the tube, avoiding the tube wall. If isolating more cells, increase the volume of Biotin-Antibody Mix proportionally.Wash cells onceAfter incubation, add Isolation Buffer to bring the volume to 1.5 mL, and centrifuge at 500 g for 5 min.Note: If isolating a very large number of cells, use a 15 mL centrifuge tube, add Isolation Buffer to 5-10 mL, then centrifuge.Resuspend cellsAfter centrifugation, discard the supernatant and resuspend the cells in 100 μL of Isolation Buffer.Note: If isolating more cells, increase the volume of Isolation Buffer proportionally.Add Streptavidin Magnetic BeadsAdd 20 μL of washed Streptavidin Magnetic Beads to the centrifuge tube (the beads must be washed before use: vortex to resuspend the beads, transfer the required volume of beads to a 1.5 mL centrifuge tube, add 1 mL of Isolation Buffer, centrifuge at 10,000 g for 1 min or use a magnetic separator for 3 min, then discard the supernatant. Add 1 mL of Isolation Buffer and wash the beads once more, then resuspend the beads in the same volume of Isolation Buffer as originally taken. For example, if 20 μL of beads are taken, resuspend them in 20 μL of Isolation Buffer after washing). Mix thoroughly and incubate at 4°C for 10 min.Note: If isolating more cells, increase the volume of Streptavidin Magnetic Beads proportionally. For example, to isolate 5×10⁷ cells, add 10 μL of Biotin-Antibody Mix and 100 μL of Streptavidin Magnetic Beads to 500 μL of cell suspension. If isolating fewer than 1×10⁷ cells, adjust the cell suspension volume to 100 μL, then add 2 μL of Biotin-Antibody Mix and 20 μL of Streptavidin Magnetic Beads.Transfer and diluteAfter incubation, transfer the mixture to a FACS tube, add Isolation Buffer to a total volume of 2.5 mL, and mix thoroughly by pipetting up and down (avoid vigorous shaking or inverting).Magnetic separationPlace the FACS tube containing the cell suspension on a magnetic separator and let stand for 5 min.Collect neutrophilsGently pour the cell suspension into a sterile centrifuge tube (do not remove the FACS tube from the magnetic separator while pouring). This cell suspension contains the purified mouse neutrophils. Centrifuge at 500 g for 5 min, then discard the supernatant and collect the cells.Resuspend for further useWash the cells as required for your experiment, then resuspend them in the desired buffer or culture medium for subsequent molecular or cell biology experiments.Isolation PerformanceNeutrophils were isolated from C57BL/6 mouse bone marrow cells. Cells before and after isolation were stained with FITC anti-mouse Ly-6G antibody (clone 1A8) and PE anti-mouse CD11b antibody (clone M1/70) and analyzed by flow cytometry. The purity of neutrophils before and after isolation was 43.5% and 95.1%, respectively.PrecautionsAvoid freezing the magnetic beads and antibody mix during use and storage.Low-retention pipette tips and centrifuge tubes are recommended to avoid loss of beads and antibodies due to adsorption.This product must be used with a magnetic separator.For research use only.


Grade: BioReagent


Storage Temperature: Store at 2-8°C;Do not freeze


Shipped in: Wet ice;Do not freeze


Specifications
UPC:
12352207
Weight:
7.06 Ounces
HazmatClass:
No
Quantity:
1
Unit of Measurement:
ST
WeightUOM:
LB
MPN:
M1522422-10T
Country of Origin:
China
Product Size:
10T
Harmonized Tariff Code:
2931.90.90
Catalog No. C008B-266887
Price: $304.93
List Price: $338.81
  • Guaranteed quality & reliable delivery
  • Shipping Lead-Time: 14-21 Days
Adding to cart… The item has been added
Request a Quote

Enjoy exclusive benefits, including discounted pricing on bulk orders, by opening a Cenmed Business Account. Learn More.